Configuration – Lenze EVF9333−xV User Manual

Page 324

Advertising
background image

Configuration

Function blocks
Internal motor control with vector control (MCTRL2)

8

8.2
8.2.7

l

8.2−62

EDSVF9333V EN 6.2−04/2012

199 %

M

100 %

80 %

n

N

2 n

N

3 n

N

n

0

1

2

9300vec153

Fig. 8.2−22

Torque characteristics when being evaluated with C0898

0 "Internal limit characteristic" when C0898 = 1 and MCTRL−HI−M−LIM = 199 %

Boost of the upper torque limit when MCTRL−HI−M−LIM = 199 % and
C0898 = 0

1 Torque characteristic when C0898 = 1 and MCTRL−HI−M−LIM = 80 %

2 Torque characteristic when C0898 = 0 and MCTRL−HI−M−LIM = 80 %

Evaluating torque limits using C0898

Code C0898 serves to evaluate the defined torque limits at the inputs
MCTRL−LO−M−LIM and MCTRL−HI−M−LIM using the function 1/f

act

. This serves

to reduce the torque.

Selection

Code

Description

Evaluation of the torque
limit in the field
weakening range

C0898 = 0

Lenze setting
The input signals at MCTRL−LO−M−LIM and
MCTRL−HI−M−LIM are evaluated with 1/f

act

.

C0898 = 1

An "internal limit characteristic" which corresponds
to a maximum torque limit of ±199,99 % is evaluated
with 1/f

act

.

l

The torque remains constant until the limit
characteristic is reached. This requires that the
controller provides a sufficient amount of current
and the motor is stable within the required speed
range.

l

The input signals at MCTRL−LO−M−LIM and
MCTRL−HI−M−LIM are not evaluated with 1/f

act

.

Advertising