Commissioning – Lenze EVF9333−xV User Manual

Page 203

Advertising
background image

Commissioning

Adjusting the motor

Automatic collection of motor data

6

6.6

6.6.6

l

6.6−15

EDSVF9333V EN 6.2−04/2012

Codes for parameter setting

Code

Possible settings

IMPORTANT

No.

Name

Lenze Selection

C0084

s

Mot Rs

à

0.00

{0.01 m

W}

100000.

00

Motor stator resistance

à

Value is determined by motor
parameter identification
(C0148, C0149)

^
6.6−1

^
6.6−14

C0087

s

Mot speed

à

50

{1 rpm}

36000 Rated motor speed

à

depending on C0086

l

Motor selection in C0086 set
the corresponding rated motor
speed in C0087

l

Change of C0087 sets
C0086 = 0

^
6.6−1

C0088

s

MOT CURRENT

à

0.5

{0.1 A}

500.0 Rated motor current

à

Depending on C0086

l

Selection of a motor in C0086
sets the corresponding rated
motor current in C0088

l

Change of C0088 sets
C0086 = 0

^
6.6−1

C0089

s

Mot frequency

à

10

{1 Hz}

5000 Rated motor frequency

à

depending on C0086

l

Motor selection in C0086 sets
the corresponding rated motor
frequency in C0089

l

Change of C0089 sets
C0086 = 0

^
6.6−1

C0090

s

Mot voltage

à

0

{1 V}

1000 Rated motor voltage

à

depending on C0086

l

Motor selection in C0086 sets
the corresponding rated motor
voltage in C0090

l

Change of C0090 sets C0086 =
0

^
6.6−1

C0091

s

Mot cos phi

à

0.50

{0.01 }

1.00 Motor cos

j

à

depending on C0086

l

Motor selection in C0086 sets
the corresponding motor cos

j

in C0091

l

Change of C0091 sets
C0086 = 0

^
6.6−1

C0092

s

Mot Ls

à

0.0

{0.1 mH}

6500.0 Motor stator inductance

à

Value is evaluated by motor
parameter identification from
C0088, C0089, C0090 and
C0091

à

Selection of a motor in C0086
sets the corresponding stator
inductance value in C0092

^
6.6−1

Advertising