Configuration – Lenze EVF9333−xV User Manual

Page 318

Advertising
background image

Configuration

Function blocks
Internal motor control with vector control (MCTRL2)

8

8.2
8.2.7

l

8.2−56

EDSVF9333V EN 6.2−04/2012

IMPORTANT

Possible settings

Code

Selection

Lenze

Name

No.

C0235 damping

5

1

{1 ms}

600 Filter time of the oscillation

damping, function block MCTRL

l

Filter time for the internal
signal for oscillation damping

^
8.2−25

^
8.2−48

C0236 damp limit

0.2

0.0

{0.1 Hz}

20.0 Limit value of oscillation damping,

function block MCTRL

l

Limit value for the internal
signal of oscillation damping

C0420

s

Encoder const

512

1

{1 inc/rev}

8192 Number of increments for

incremental encoder at X8 or X9

l

Connect incremental encoders
with HTL−level on X9 only

^ 6.7−1

C0421

s

Enc voltage

5.00

5.00

{0.1 V}

8.00 Supply voltage for the incremental

encoder at X8
CAUTION! A wrong entry can
destroy the incremental encoder!

C0497 Nact filter

2.0

0.0

{0.1 ms}

50.0 Filter time constant N

act

for actual

speed value, function block
MCTRL2

l

Internal filtering of the speed
signal for control

l

C0497 = 0 ms: Switched off

^
8.2−48

C0890

s

CFG: N−SET

5050 NSET−NOUT

^ Selection list 1

Configuration of analog input
signal, function block MCTRL

l

Speed setpoint

^
8.2−25

^
8.2−48

C0891

s

CFG: M−Add

1000 FIXED0%

^ Selection list 1

Configuration of analog input
signal, function block MCTRL

l

Additional torque setpoint or
torque setpoint

^
8.2−48

C0892

s

CFG: Lo−M−LIM

5700 ANEG1−OUT

^ Selection list 1

Configuration of analog input
signal, function block MCTRL

l

Lower torque limit in [%] of
C0057

C0893

s

CFG: HI−M−LIM

19523 FCODE−472/3

^ Selection list 1

Configuration of analog input
signal, function block MCTRL

l

Upper torque limit in [%] of
C0057

C0898

s

CFG: M−LIM
switch

0

0

M−LIM ON

Reduced torque
limit is active

Torque limitation in the field
weakening range, function block
MCTRL

l

If the torque limit is reduced,
the maximum possible torque
in the field weakening range is
lowered with 1/f. This provides
a higher motor stability in the
field weakening range

^
8.2−48

1

M−LIM OFF

Reduced torque
limit is inactive

C0899

s

CFG: N/M−SWT

1000 FIXED0

^ Selection list 2

Configuration of digital input
signal, function block MCTRL

l

LOW = active speed control

l

HIGH = active torque control

^
8.2−48

C0900

s

CFG: QSP

10250 R/L/Q−QSP

^ Selection list 2

Configuration of digital input
signal, function block MCTRL

l

HIGH = drive performs quick
stop

^
8.2−25

^
8.2−48

Advertising
This manual is related to the following products: