9 mains choke/mains filter assignment, Mains choke/mains filter assignment, Wiring of the standard device – Lenze EVF9333−xV User Manual

Page 92

Advertising
background image

Wiring of the standard device

Notes on project planning
Mains choke/mains filter assignment

5

5.2
5.2.9

l

5.2−8

EDSVF9333V EN 6.2−04/2012

5.2.9

Mains choke/mains filter assignment

Operation with rated power (normal operation)

9300

Mains choke

Interference voltage category according to EN 61800−3 and motor cable length

Component

Component

Type

C2

max. [m]

C1

max. [m]

EVF9321−xV

EZN3A2400H002

EZN3A2400H002

5

EZN3B2400H002

50

EVF9322−xV

EZN3A1500H003

EZN3A1500H003

5

EZN3B1500H003

50

EVF9323−xV

EZN3A0900H004

EZN3A0900H004

5

EZN3B0900H004

50

EVF9324−xV

EZN3A0500H007

EZN3A0500H007

5

EZN3B0500H007

50

EVF9325−xV

EZN3A0300H013

EZN3A0300H013

5

EZN3B0300H013

50

EVF9326−xV

ELN3−0150H024−001

EZN3A0150H024

5

EZN3B0150H024

50

EVF9327−xV

ELN3−0088H035−001

EZN3A0110H030

25

E82ZN22334B230

10

E82ZZ15334B230

1)

10

E82ZN22334B230

50

EZN3B0110H030U

2)

50

E82ZZ15334B230

1)

50

EVF9328−xV

ELN3−0075H045

EZN3A0080H042

25

E82ZN22334B230

10

E82ZN22334B230

50

EZN3B0080H042

50

EVF9329−xV

ELN3−0055H055

EZN3A0055H060

25

E82ZN30334B230

10

E82ZN30334B230

50

EZN3B0055H060

50

EVF9330−xV

ELN3−0038H085

EZN3A0037H090

25

E82ZN45334B230

10

E82ZN45334B230

50

EZN3B0037H090

50

EVF9331−xV

ELN3−0027H105−001

EZN3A0030H110

25

E82ZN55334B230

10

EZN3A0030H110N001

3)

25

E82ZN55334B230

50

EZN3B0030H110

50

EVF9332−xV

ELN3−0022H130

EZN3A0022H150

25

E82ZN75334B230

10

E82ZN75334B230

50

EZN3B0022H150

50

EVF9333−xV

ELN3−0017H170

EZN3A0017H200

25

E82ZN90334B230

10

E82ZN90334B230

50

EZN3B0017H200

50

1)

RFI filter

2)

Footprint filter

3)

For controllers with thermal separation

Advertising
This manual is related to the following products: