3 master frequency output (dfout), Master frequency output (dfout), Configuration – Lenze EVF9333−xV User Manual

Page 270: Function blocks master frequency output (dfout)

Advertising
background image

Configuration

Function blocks
Master frequency output (DFOUT)

8

8.2
8.2.3

l

8.2−8

EDSVF9333V EN 6.2−04/2012

8.2.3

Master frequency output (DFOUT)

The function block creates rectangular signals from an analog signal or
speed signal, which are output via X10. Alternatively, you can set the master
frequency output to a signal output at X8 or X9.

C0030
C0540

CTRL

DFOUT-AN-IN

C0547

C0541

DFOUT-DF-IN

C0549

C0542

C0548

C0544

DFOUT-SYN-RDY

DFOUT-OUT

DFOUT

C0545

1

0

2

3

4

5

X8

X9

X10

C0540

E5

X5

fb_dfout

Fig. 8.2−7

Digital frequency output (DFOUT)

Codes for parameter setting

Code

Possible settings

IMPORTANT

No.

Name

Lenze Selection

C0030 DFOUT const

3

0

256 inc/rev

Function block DFOUT

l

Setting of the constant
(increments per revolution) for
the master frequency output
X10

^
8.2−8

1

512 inc/rev

2

1024 inc/rev

3

2048 inc/rev

4

4096 inc/rev

5

8192 inc/rev

6

16384 inc/rev

Description