Commissioning – Lenze EVF9333−xV User Manual
Page 213
Commissioning
Operating mode
6.8
l
6.8−3
EDSVF9333V EN 6.2−04/2012
The following table helps you to find the correct operating mode for
standard applications:
ƒ C0006 = 5: V/f characteristic control with constant U
min
boost
ƒ C0006 = 1: vector control
Power range 0.37 ... 90 kW
Selection of the operating mode in C0006
Motor cable
shielded
£
50 m
unshielded
£
100 m
Motor cable
shielded
>
50 m
unshielded
>
100 m
recommen
ded
alternativ
ely
recommen
ded
alternativ
ely
Single drives
With constant load
1
5
5
−
With extremely alternating loads
1
5
5
−
With high starting duty
1
5
5
−
Positioning and infeed drives with high
dynamics
1
5
5
−
Rewinder with dancer
1
5
−
−
Unwinder with dancer
5
−
−
−
Pump and fan drives
1)
5
−
5
−
Three−phase AC reluctance motors
5
−
5
−
Three−phase AC sliding rotor motors
5
−
5
−
Three−phase AC motors with fixed
voltage/frequency characteristic
5
−
5
−
Group drives
(the resulting motor cable length I
res
) is
decisive
l
res
+ i
Ǹ
@ (l
1
) l
2
) AAA ) l
i
)
Identical motors and identical loads
1
5
5
−
Different motors and/or alternating loads
5
−
5
−
1)
For this application we recommend a quadratic voltage characteristic (C0014 = 1)
)
Note!
Only switch between the operating modes if the controller is
inhibited!
Operating modes
recommended for standard
applications