Configuration – Lenze EVF9333−xV User Manual

Page 265

Advertising
background image

Configuration

Function blocks

Diameter calculator (DCALC)

8

8.2

8.2.1

l

8.2−3

EDSVF9333V EN 6.2−04/2012

By division of the speed signals at DCALC1−N−LINE and DCALC1−N−WIND, the
current diameter is calculated.

ƒ The signal at DCALC1−N−LINE has to correspond to the circumferential

speed of the reel.

ƒ The signal at DCALC1−N−WIND has to be proportional to the reel speed.

ƒ You have to adapt the signal at DCALC1−N−LINE in C1300 and C1301, so

that the value calculated corresponds to the actual diameter. The
nominal reel diameter d

max

is entered in C1304.

– For operation with the nominal reel diameter d

max

you have to enter

the value at input DCALC1−N−WIND in C1300 and the value at input
DCALC1−N−LINE in C1301.

ƒ The input signals are integrated cyclically. In C1302 you alter the

integration interval (calculation cycle):
Great value in C1302

Þ high resolution

Low value in C1302

Þ low resolution

ƒ If the integrator overflows, DCALC1−OVFL is set to HIGH. The integrator

is reset internally and starts again with the calculation of the last
correct value.

ƒ A first−order low pass filters the values calculated. The filter time

constant is set via C1303.

In C1328 the current diameter is displayed.

ƒ For the conversion of the scaled calculated value to the absolute value

[mm], the reference diameter d

max

has to be entered via C1304.

ƒ At DCALC1−D−OUT the current diameter is output. The signal is scaled

to the value in C1304.

With DCALC1−HOLD = HIGH the last diameter value calculated is
maintained and the integrators are reset.

ƒ When the controller is switched off, the current diameter value is

saved. When it is switched on, the last value saved is loaded.

In C1305 the minimum diameter (d

min

) in [mm] is entered. d

min

is reached

when DCALC1−DMIN switches to HIGH.

In C1306 the maximum diameter (d

max

) in [mm] is entered. d

max

is reached

when DCALC1−DMAX switches to HIGH.

In C1307 a hysteresis for resetting the display signal is set. The entry in [%]
relates to the absolute values in C1305 and C1306.

Calculating the diameter

Displaying the diameter

Maintaining/saving the
current value

Setting/displaying the
diameter

Advertising
This manual is related to the following products: