Chapter 8
Using Basic Instructions

8–5

Using LDI

Use the LDI instruction for normally closed contacts that appears first on a
rung or block.

Entering the Instruction

You enter the instruction from within the program monitor functional area.

P 0 0 0

/

I / 6

0

Using ANI

Use the ANI instruction for normally closed contacts placed in series with
any previous input instruction in the current rung or block.

Entering the Instruction

You enter the instruction from within the program monitor functional area.

P 0 0 0

/

I / 7

0

Using ORI

Use the ORI instruction for normally closed contacts placed in parallel with
any previous input instruction in the current rung or block.

Entering the Instruction

You enter the instruction from within the program monitor functional area.

P 0 0 0

/

B / 0

1

4

LDI

To access the LDI instruction, press:

5

ANI

To access the ANI instruction, press:

6

ORI

To access the ORI instruction, press: