Chapter 8
Using Basic Instructions
8–5
Using LDI
Use the LDI instruction for normally closed contacts that appears first on a
rung or block.
Entering the Instruction
You enter the instruction from within the program monitor functional area.
P 0 0 0
/
I / 6
0
Using ANI
Use the ANI instruction for normally closed contacts placed in series with
any previous input instruction in the current rung or block.
Entering the Instruction
You enter the instruction from within the program monitor functional area.
P 0 0 0
/
I / 7
0
Using ORI
Use the ORI instruction for normally closed contacts placed in parallel with
any previous input instruction in the current rung or block.
Entering the Instruction
You enter the instruction from within the program monitor functional area.
P 0 0 0
/
B / 0
1
4
LDI
To access the LDI instruction, press:
5
ANI
To access the ANI instruction, press:
6
ORI
To access the ORI instruction, press: