Chapter 13
Using Application Specific Instructions

13–11

Operation

The operation of the SQC instruction is shown in the figure below. The
screens shown above the figure are the condensed screens that appear after
instruction entry is complete.

P 0 1 4

S Q C

F I L E

# B 8

0 0 0 0 H

P 0 1 4

S Q C

M A S K

F F F 0 H

P 0 1 4

S Q C

S R C

I 0

0 0 0 0 H

P 0 1 4

S Q C

R 0 3

L

4

P

2

0010

0100

1001

1101

1111

1111

1111

0000

0010

0100

1001

1010

0
1
2
3
4

Step

B8

9

10
11
12

Word

Input Word I0

Mask Value FFF0

Sequencer Ref File #B8

The SQC FD bit is set when the instruction detects that an input
word matches (thru mask) its corresponding reference word.

The FD bit R3/FD is set in this example, since the input word
matches the sequencer reference value using the mask value.