Recommended User-Supplied Components

These components can be purchased from your local electronics supplier.

Component

Recommended Model

external power supply and chassis
ground

power supply rated for 20.4–28.8V dc

NULL modem adapter

standard AT

straight 9–25 pin RS-232 cable

see table below for port information if making own cables

DH-485 connector Port 3



DB-9 RS-232 Port 1

cable straight D connector

8-pin mini DIN

1761-CBL-AP00 or 1761-CBL-PM02



































Item

Port 1

DB-9 RS-232

Port 2

(1761-CBL-PM02 cable)

Port 3

DH-485 Connector



received line signal detector (DCD)

same state as port 1’s DCD signal

chassis ground



received data (RxD)

received data (RxD)

cable shield



transmitted data (TxD)

transmitted data (TxD)

signal ground



DTE ready (DTR)

DTE ready (DTR)

DH-485 data B



signal common (GRD)

signal common (GRD)

DH-485 data A



DCE ready (DSR)

DCE ready (DSR)

termination

request to send (RTS)

request to send (RTS)

not applicable

clear to send (CTS)

clear to send (CTS)

not applicable

not applicable

not applicable

not applicable

An 8-pin mini DIN connector is used for making connections to port 2. This connector is not commercially
available. If you are making a cable to connect to port 2, you must configure your cable to connect to the
Allen-Bradley cable shown above.

On port 1, pin 4 is electronically jumpered to pin 6. Whenever the AIC+ is powered on, pin 4 will match the
state of pin 6.

In the 1761-CBL-PM02 cable, pins 4 and 6 are jumpered together within the DB-9 connector.