Controller Mode
Options
Active Controller Mode
Chapter 4
Using Your Hand-Held Programmer
4–10
Mode
From the mode functional area, you can change the current mode of the
controller.
Screen Definition
The following figure shows the mode screen and identifies its main sections.
A C T I V E
M O D E : R P R G
R P R G
R R U N
Section
Description
Active Controller Mode
The current mode of the controller is displayed. See the
table below for a list of the possible display entries.
Controller Mode
Options
The controller mode options you can select (RPRG,
RRUN, RCSN, and RSSN) are accessed from this
screen using the arrow keys. Descriptions of each of
these modes and how you change between them can be
found beginning on page 18–21.
The table below shows the possible active controller mode display entries
and the corresponding micro controller mode.
Display Entry
Micro Controller Mode
RPRG
Remote Program
RRUN
Remote Run
RCSN
Remote Test – Continuous Scan
RSSN
Remote Test – Single Scan
RSUS
Remote Suspend
➀
FLT
Fault
➁
➀ The controller only enters suspend mode if you run a program that executes a suspend instruction.
➁ The controller only enters fault mode if, while a program is executing, a fault occurs within the operating
system or the program, or if S1/13 is set at any time. See page 20–11 for information on identifying and
clearing faults.