Chapter 13
Using Application Specific Instructions

13–22

Rung 4:2
Is identical to the previous rung except that it is only active when the
”hole selector switch” is in the ”5–hole” position.

| hole |hole 5 hole |
| selector |selector preset |
| switch |switch sequencer |
| bit 0 |bit 1 |
| I:0 I:0 +SQO–––––––––––––––+ |
|––––] [––––––––]/[–––––––––––––––––––––+–+SEQUENCER OUTPUT +–(EN)–+–|
| 9 10

| |File #N7:55+–(DN) | |

| | |Mask FFFF| | |
| | |Dest N7:7| | |
| | |Control R6:5| | |
| | |Length 7| | |
| | |Position 0| | |
| | +––––––––––––––––––+ | |
| | force the | |
| | sequencer | |
| | to increment | |
| | on the next | |
| | scan | |
| | R6:5 | |
| +––––(U)––––––––––––––––––––+ |
| EN |

Rung 4:3

➀➂

Is identical to the two previous rungs except that it is only active when
the ”hole selector switch” is in the ”7–hole” position.

| hole |hole 7 hole |
| selector |selector preset |
| switch |switch sequencer |
| bit 0 |bit 1 |
| I:0 I:0 +SQO–––––––––––––––+ |
|––––] [––––––––] [–––––––––––––––––––––+–+SEQUENCER OUTPUT +–(EN)–+–|
| 9 10 | |File #N7:62+–(DN) | |
| | |Mask FFFF| | |
| | |Dest N7:7| | |
| | |Control R6:6| | |
| | |Length 9| | |
| | |Position 0| | |
| | +––––––––––––––––––+ | |
| | force the | |
| | sequencer | |
| | to increment | |
| | on the next | |
| | scan | |
| | R6:6 | |
| +––––(U)––––––––––––––––––––+ |
| EN |

This rung accesses I/O only available with 32 I/O controllers. Therefore, do not include this rung if you are using a 16
I/O controller.

This instruction accesses I/O only available with 32 I/O controllers. Therefore, do not include this instruction if you are
using a 16 I/O controller.

More rungs will be added to this subroutine at the end of chapter 14.