background image

Chapter 3
Connecting the System

3–8

Cable Selection Guide

1747-CP3

1761-CBL-AC00

Cable

Length

Connections from

to AIC+

External

Power Supply

Required

Power Selection Switch

Setting

1747-CP3

1761

L

00

3m (9.8 ft)

c

17 7 i

SLC 5/03 or SLC 5/04 processor, channel 0

port 1

yes

external

17 7 P3

1761-CBL-AC00

3

9

f

45 cm (17.7 in)

PC COM port

port 1

yes

external

PanelView 550 through NULL modem adapter

port 1

yes

external

Port 1 on another AIC+

port 1

yes

external

1761-CBL-AS03

1761-CBL-AS09

Cable

Length

Connections from

to AIC+

External

Power Supply

Required

Power Selection Switch

Setting

1761-CBL-AS03

1761-CBL-AS09

3m (9.8 ft)

9.5m (31.17 ft)

SLC 500 Fixed,
SLC 5/01, SLC 5/02, and SLC 5/03 processors

port 3

yes

external

1761-CBL-AS09

9.5m (31.17 ft)

PanelView 550 RJ45 port

port 3

yes

external

1761-CBL-AM00

1761-CBL-HM02

Cable

Length

Connections from

to AIC+

External

Power Supply

Required

Power Selection Switch

Setting

1761-CBL-AM00

45 cm (17.7 in)

2

6

f

MicroLogix 1000

port 2

no

cable

1761

L M00

1761-CBL-HM02

c

17 7 i

2m (6.5 ft)

to port 2 on another AIC+

port 2

yes

external

External power supply required unless the AIC+ is powered by the device connected to port 2, then the
selection switch should be set to cable.

Series B cables or higher are required for hardware handshaking.