After You’ve Entered Your Program
Chapter 18
18–29
Integer Data File
To access integer data file N3:
ENT
SEARCH
N
MON
3
U
N 3
1 0 0
Changing the Radix
Radix refers to the way numeric-based information is displayed. You can
change the radix for output, input, bit, and integer data files. Since the
displays for timer, counter, control, and status data files are pre-formatted,
the option of changing the radix is not available for those data files.
The radix choices are:
•
binary (default radix for output, input, and bit files)
•
hexadecimal
•
decimal (default radix for integer file)
Important: When you exit the data monitor, the display remains in the last
radix you selected.
In the following example the display of an output file is changed from binary
to hexadecimal to decimal and back to binary.
1. Access the output data table file.
O
MODE
MON
ENT
O / 0
O 0
F O N
0 0 0 0 1 1 1 1 0 0 0 0 1 0 1 1
The output file defaults to a binary display.
2. Change the display to a hexadecimal radix using the hot key sequence.
FUN
ANB
0
O 0
0 F 0 B H