Monitoring your controller – Rockwell Automation 1761-HHP-B30 MicroLogix 1000 with Hand-Held Programmer (HHP) User Manual

Page 345

Advertising
background image

After You’ve Entered Your Program

Chapter 18

18–24

This section shows you how to monitor the program files and data table files.
If a fault occurs while monitoring your controller, follow the procedure on
page 20–11 to clear the fault.

Monitoring Program Files

Program files contain controller information, the main instruction list
program, and any subroutine programs. Monitoring your program files
allows you to watch the instruction parameters of timers, counters, and
accumulated values change, and to see bits turn on and off as your program
runs.

To monitor a program file, follow these steps:

1. From the home screen or data monitor, access the program monitor

display for the program.

MON

ENT

R

S T A R T

F I L E : 0 2

M I C R O

You return to the last location you were at within the program.

2. Arrow to the program file you want to monitor and move through the

rungs, as described in the table below:

To:

Press:

move up and down through a program’s
rungs and program files

move left and right through each rung of a
program. (When the end of a rung is reached
the next rung automatically scrolls into view
as you move the cursor right or left in the
program.)

Monitoring Your Controller