Paper Drilling Machine Ladder Program

Rung 2:0
Initializes the high-speed counter each time the RRUN mode is entered.
The high-speed counter data area (N7:5 – N7:9) corresponds with the
starting address (source address) of the HSL instruction. The HSC
instruction is disabled each entry into the RRUN mode until the first time
that it is executed as true. (The high preset was ”pegged” on
initialization to prevent a high preset interrupt from occurring during
the initialization process.)

| 1’st Output Mask |
| Pass (only use bit 0 |
| ie. O:0/0) |
| S:1 +MOV–––––––––––––––+ |
|––––] [–––––––––––––––––––––––––––––––––––––+–+MOVE +–+–|
| 15 | |Source 1| | |
| | | | | |
| | |Dest N7:5| | |
| | | 0| | |
| | +––––––––––––––––––+ | |
| | High Output Pattern | |
| | (turn off O:0/0) | |
| | | |
| | +MOV–––––––––––––––+ | |
| +–+MOVE +–+ |
| | |Source 0| | |
| | | | | |
| | |Dest N7:6| | |
| | | 0| | |
| | +––––––––––––––––––+ | |
| | High Preset Value | |
| | (counts to next hole)| |
| | |
| | +MOV–––––––––––––––+ | |
| +–+MOVE +–+ |
| | |Source 32767| | |
| | | | | |
| | |Dest N7:7| | |
| | | 0| | |
| | +––––––––––––––––––+ | |
| | Low output pattern | |
| | (turn on O:0/0 | |
| | each reset) | |
| | |
| | +MOV–––––––––––––––+ | |
| +–+MOVE +–+ |
| | |Source 1| | |
| | | | | |
| | |Dest N7:8| | |
| | | 0| | |
| | +––––––––––––––––––+ | |
| | Low preset value | |
| | (cause low preset | |
| | int at reset) | |
| | |
| | +MOV–––––––––––––––+ | |
| +–+MOVE +–+ |
| | |Source 0| | |
| | | | | |
| | |Dest N7:9| | |
| | | 0| | |
| | +––––––––––––––––––+ | |
| | High Speed Counter | |
| | | |
| | +HSL–––––––––––––––+ | |
| + –+HSC LOAD +–+ |
| |Counter C5:0| |
| |Source N7:5| |
| |Length 5| |
| +––––––––––––––––––+ |