Rockwell Automation 1761-HHP-B30 MicroLogix 1000 with Hand-Held Programmer (HHP) User Manual

Page 530

Advertising
background image

(HHP) User Manual

Index
MicroLogix

t 1000 with Hand-Held Programmer

I–26

First Instruction on Rung, 17–2
home, 4–7
menu, 4–9
mode, 4–10
multi-point function, 4–15
program monitor, 4–11
Start of File, 17–1
Start of Rung, 17–2

searching for specific addresses, 17–8

addresses that are displayed, 17–8
addresses you enter, 17–8
bit versus word addresses, 17–9

Selectable Timed Disable (STD), 13–17

entering the instruction, 13–17
example, 13–17
execution times, 13–17
function code, 13–17
instruction parameters, C–9
ladder representation, 13–17
using, 13–17
valid addressing modes, C–9
valid file types, C–9

Selectable Timed Enable (STE), 13–17

entering the instruction, 13–17
example, 13–17
execution times, 13–17
function code, 13–17
instruction parameters, C–9
ladder representation, 13–17
using, 13–17
valid addressing modes, C–9
valid file types, C–9

Selectable Timed Interrupt (STI) function

basic programming procedure, 13–15
Interrupt Subroutine (INT), 13–19
operation, 13–15

interrupt latency and interrupt

occurrences, 13–16

interrupt priorities, 13–16
status file data saved, 13–16
subroutine content, 13–15

overview, 13–15
Selectable Timed Disable (STD), 13–17
Selectable Timed Enable (STE), 13–17
Selectable Timed Start (STS), 13–18
STD/STE zone example, 13–17

Selectable Timed Start (STS), 13–18

entering the instruction, 13–19
execution times, 13–18
function code, 13–19
instruction parameters, C–10
ladder representative, 13–18
valid addressing modes, C–10

valid file types, C–10

Selecting Surge Suppressors, 1–7

selecting the language

using short-cut keys, 4–18
using the menu option, 4–17

Sequencer Compare (SQC), 13–6

entering parameters, 13–6
entering the instruction, 13–10
execution times, 13–6
function code, 13–10
instruction parameters, C–9
ladder representation, 13–6
operation, 13–11
using, 13–10
valid addressing modes, C–9
valid file types, C–9

sequencer instructions

overview, 13–6

effects on index register S:24, 13–6
entering the instructions, 13–6

Sequencer Compare (SQC), 13–6
Sequencer Load (SQL), 13–12
Sequencer Output (SQO), 13–6

Sequencer Load (SQL), 13–12

entering parameters, 13–12
entering the instruction, 13–13
execution times, 13–12
function code, 13–13
instruction parameters, C–9
ladder representation, 13–12
operation, 13–14
valid addressing modes, C–9
valid file types, C–9

Sequencer Output (SQO), 13–6

entering parameters, 13–6
entering the instruction, 13–8
execution times, 13–6
function code, 13–8
instruction parameters, C–9
ladder representation, 13–6
operation, 13–9
using, 13–7
valid addressing modes, C–9
valid file types, C–9

series logic (AND), 6–12

Set (SET), 8–8

entering the instruction, 8–9
execution times, 8–8
instruction parameters, C–9
ladder representation, 8–8
using, 8–9
valid addressing modes, C–9

Advertising