Appendix B
Programming Reference

B–2

Word

Function

Page

S:23

Reserved

B–12

S:24

Index Register

B–12

S:25 to S:29

Reserved

B–12

S:30

STI Setpoint

B–12

S:31 and S:32

Reserved

B–12

Status File Descriptions

The following tables describe the status file functions, beginning at address
S0 and ending at address S32.

Each status bit is classified as one of the following:

Status — Use these words, bytes, or bits to monitor controller operation
or controller status information. The information is seldom written to by
the user program or programming device (unless you want to reset or
clear a function such as a monitor bit).

Dynamic Configuration — Use these words, bytes, or bits to select
controller options while online with the controller.

Static Configuration — Use these words, bytes, or bits to select controller
options prior to saving the user program.

Address

Bit

Classification

Description

S0

Arithmetic and
Scan Status
Flags

The arithmetic flags are assessed by the controller following the
execution of certain math and data handling instructions. The
state of these bits remain in effect until certain math or data
handling instructions in the program are executed.

S0/0

Carry

Status

This bit is set by the controller if a mathematical carry or borrow is
generated. Otherwise the bit remains cleared. This bit is
assessed as if a function of unsigned math. When a STI,
high-speed counter, or Fault Routine interrupts normal execution
of your program, the original value of S:0/0 is restored when
execution resumes.

S0/1

Overflow

Status

This bit is set by the controller when the result of a mathematical
operation does not fit in its destination. Otherwise the bit remains
cleared. Whenever this bit is set, the overflow trap bit S:5/0 is
also set except for the ENC bit. Refer to S:5/0. When a STI,
high-speed counter, or Fault Routine interrupts normal execution
of your program, the original value of S:0/1 is restored when
execution resumes.

S0/2

Zero

Status

This bit is set by the controller when the result of certain math or
data handling instructions is zero. Otherwise the bit remains
cleared. When a STI, high-speed counter, or Fault Routine
interrupts normal execution of your program, the original value of
S:0/2 is restored when execution resumes.

S0/3

Sign

Status

This bit is set by the controller when the result of certain math or
data handling instructions is negative. Otherwise the bit remains
cleared. When a STI, high-speed counter, or Fault Routine
interrupts normal execution of your program, the original value of
S:0/3 is restored when execution resumes.

S0/4 to S0/7

Reserved

NA

NA