Appendix B
Programming Reference

B–10

Fault Classification

User

Address

Error
Code
(Hex)

Run Errors

Non-User

Non-

Recoverable

Recoverable

S6

0004

A runtime memory integrity error occurred.

X

0020

A minor error at the end of the scan.
Refer to S:5.

X

0022

The watchdog timer expired. Refer to
S:3H.

X

0024

Invalid STI interrupt setpoint. Refer to
S:30.

X

0025

There are excessive JSRs in the STI
subroutine (file 5).

X

0027

There are excessive JSRs in the fault
subroutine (file 3).

X

002A

The indexed address is too large for the
file.

X

002B

There are excessive JSRs in the high-
speed counter subroutine (file 4).

X

0030

The subroutine nesting exceeds a limit of
8 (file 2).

X

0031

An unsupported instruction was detected.

X

0032

An SQO/SQC instruction crossed data file
boundaries.

X

0033

The LFU, LFL, FFU, FFL, BSL, or BSR
instruction crossed data file boundaries.

X

0034

A negative value for a timer accumulator
or preset value was detected.

X

0035

An illegal instruction (TND) occurred in the
interrupt file.

X

0037

Invalid presets were loaded to the
high-speed counter.

X

0038

A RET instruction was detected in
program file 2.

X

0040

An output verify write occurred.

X

0041

Extra output bit(s) turned on.

X

Valid for Series A–C discrete only.

Fault Classification

User

Address

Error
Code
(Hex)

Saving to Controller or Loading from

Memory Module Errors

Non-User

Non-

Recoverable

Recoverable

S6

0018

The user program is incompatible with the
operating system.

X