FlexPak 3000 DC Drive Software Reference

OCL

PI

PROP

GAIN

(P.808)

The proportional gain
of the outer control
loop

PI

block.

Parameter Range:

0.10 to 128.00

Default Setting:

2.00

Parameter Type:

Tunable

OIM Menu Path(s):

Outer Control Loop (

OCL

) -

OCL

Tuning

OCL

PROP

TRIM

SELECT

(P.813)

When

ENABLED

is

selected, the

OCL

output is proportional
to the absolute value
of the speed
reference at the
output of the speed
loop S-curve block.

Parameter Range:

DISABLED

ENABLED

Default Setting:

DISABLED

Parameter Type:

Configurable

OIM Menu Path(s):

Additional Parameters (listed by parameter number)

OCL

TRIM

RANGE

(P.812)

The trim range for the
outer control loop.

Parameter Range:

–100. to 100.0% of

TOP

SPEED

(P.011)

Default Setting:

0.0%

Parameter Type:

Tunable

OIM Menu Path(s):

Outer Control Loop (

OCL

) -

OCL

Tuning

This parameter specifies the amount of control the ocl output signal has on the
speed/voltage loop reference or the

CML

reference when the drive is configured as

a Type III position regulator.