13.9 Checking Drive Information

You can use these parameters to determine your drive regulator type, if your power
unit is S6R (regenerative) or S6 (non-regenerative), and regulator software version.

J

15

REGULATOR

TYPE

(P.799)

Indicates the position of jumper

J

15,

REGULATOR

TYPE

. This

jumper selects the type of
regulator,

SPEED

/

VOLTAGE

or

CURRENT

/

TORQUE

. This jumper

is only read at powerup.

Parameter Range:

SPEED

/

VOLTAGE

CURRENT

/

TORQUE

Default Setting:

n/a

Parameter Type:

Output

OIM Menu Path(s):

Drive Information
Current Minor Loop (

CML

) -

CML

Test Points

When the drive is configured as a speed regulator (J15 on the Regulator
board set to

SPEED

), the input selected by

AUTO

REFERENCE

SELECT

(P.103)

is used as a speed reference.

When the drive is configured as a torque regulator, (J15 on the Regulator
board set to

CURRENT

), the input selected by

AUTO

REFERENCE

SELECT

(P.103) is used as a torque reference to the current minor loop.

See the hardware manual for information on setting J15.

POWER

UNIT

TYPE

(P.795)

Indicates if the drive uses an
S6R (regenerative) or an S6
(non-regenerative) power unit.

Parameter Range:

S6 (

NON

-

REGEN

)

S6R (

REGEN

)

Default Setting:

n/a

Parameter Type:

Output

OIM Menu Path(s):

Drive Information

If the power unit type is S6 (non-regenerative),

NEGATIVE

CURRENT

LIM

(P.006) will be automatically fixed to 0, and

REVERSE

DISABLE

(P.015) fixed

to

DISABLE

(preventing reverse direction).

REGULATOR

SW

VERSION

(P.794)

Lists the regulator software
version.

Parameter Range:

n/a

Default Setting:

n/a

Parameter Type:

Output

OIM Menu Path(s):

Drive Information