Ppendix, Parameter settings record – Rockwell Automation FlexPak 3000 Digital DC Drive Version 4.3 User Manual
Page 163
![background image](/manuals/581746/163/background.png)
C-1
A
PPENDIX
C
Parameter Settings Record
This table provides space for you to record input parameter settings for reference.
Table C.1 – Parameter Settings Quick Reference Table
Parameter
Parameter Selection/
Adjustment Range
Initial Factory
Setting (Default)
Your Data
Date
Setting
ACCELERATION
TIME
(P.001)
0.1 to 300.0 seconds
5.0 seconds
AMX
NETW
REF
SELECT
(P.911)
•
DIRECT
•
BROADCAST
n (n=1 to 8)
DIRECT
ANALOG
TACH
GAIN
ADJ
(P.201)
0.750 to 1.250
1.000
ANALOG
TACH
ZERO
ADJ
(P.202)
–200 to 200
0
ANLG
AUTO
GAIN
ADJ
(P.101)
0.750 to 1.250
1.000
ANLG
AUTO
SIGNAL
TYPE
(P.100)
• 0– 10V
• +/–10 V
• 4-20 mA
• 10 -50mA
0– 10V
ANLG
AUTO
ZERO
ADJ
(P.102)
–200 to 200
0
ANLG
IN
1
GAIN
ADJ
(P.415)
0.750 to 2.250
1.000
ANLG
IN
1
SIG
TYPE
(P.413)
• 0– 10 V
• +/–10 V
• 4-20 mA
• 10-50 mA
+/–10 V
ANLG
IN
1
ZERO
ADJ
(P.414)
–200 to 200
0
ANLG
IN
2
GAIN
ADJ
(P.417)
0.750 to 2.250
1.000
ANLG
IN
2
ZERO
ADJ
(P.416)
–200 to 200
0
ANLG
MAN
REF
GAIN
ADJ
(P.104)
0.750 to 1.250
1.000
ANLG
MAN
REF
ZERO
ADJ
(P.105)
–200 to 200
0
ANLG
OUT
1
GAIN
ADJ
(P.420)
0.500 to 1.300
1.000