12-4
FlexPak 3000 DC Drive Software Reference
LEVEL
DETECT
2
THRESH
(P.606)
The threshold for
level detector 2.
Parameter Range:*
0.1 to 100.0% or
MAXIMUM
CURRENT
Default Setting:
10.0%
Parameter Type:
Tunable
OIM Menu Path(s):
Input/Output - Level Detectors
When the absolute value of the signal driving level detector 2 is greater than or
equal to this threshold, the associated timer starts. If the input signal is less than
this threshold, the timer is immediately reset and the level detector output is set to
OFF
.
*The parameter range for the level detector is automatically rescaled for speed or
current based on the input selected by
LEVEL
DETECT
2
SELECT
(P.605). If
CML
FEEDBACK
is selected for
LEVEL
DETECT
2
SELECT
, the parameter range is 0.1 to
MAXIMUM
CURRENT
. For any other
LEVEL
DETECT
2
SELECT
settings, the parameter
range is 0.1 to 100.0%.