P.299) – Rockwell Automation FlexPak 3000 Digital DC Drive Version 4.3 User Manual

Page 66

Advertising
background image

5-18

FlexPak 3000 DC Drive Software Reference

SPD

LOOP

OUTPUT

(P.299)

Speed loop

PI

block

output value.

Parameter Range:

n/a

Default Setting:

n/a

Parameter Type:

Output

OIM Menu Path(s):

SPD

- Speed/Voltage Loop (

SPD

) Test Points

Current Minor Loop (

CML

) -

CML

Test Points

SPD

LOOP

PI

INIT

SEL

Selects the source for
the initial value of the
speed loop

PI

block

when

CONTROL

SOURCE

SELECT

is set

to

NETWORK

.

If

CONTROL

SOURCE

SELECT

is not set to

NETWORK

,

SPD

LOOP

PI

INIT

SEL

is forced to

ZERO

.

Parameter Range:

0 =

ZERO

1 =

SPD

LOOP

PI

INIT

VAL

2 =

ANALOG

MAN

TRIM

REF

(P.194)

Default Setting:

0

Parameter Type:

Configurable

OIM Menu Path(s):

This parameter is available over the network, It
cannot be viewed through the

OIM

.

Refer to the appropriate network communication manual for register map
assignments.

SPD

LOOP

PI

INIT

VAL

The initial value of the
speed loop

PI

block

when

CONTROL

SOURCE

SELECT

is set

to

NETWORK

and

SPD

LOOP

PI

INIT

SEL

is set

to 1 (

SPD

LOOP

PI

INIT

VAL

).

Parameter Range:

–32768 to 32767

Default Setting:

0

Parameter Type:

Tunable

OIM Menu Path(s):

This parameter is only available over the network, It
cannot be viewed through the

OIM

.

This parameter is forced to 0 if

CONTROL

SOURCE

SELECT

is not set to

NETWORK

.

Refer to the appropriate network communication manual for register map
assignments.