6-10

FlexPak 3000 DC Drive Software Reference

ARMATURE

DELTA

(P.399)

Indicates the
armature firing angle
in microseconds.

Parameter Range:

n/a

Default Setting:

n/a

Parameter Type:

Output

OIM Menu Path(s):

Current Minor Loop (

CML

) -

CML

Test Points

Current Minor Loop (

CML

) -

SCR

Diagnostics -

Armature Phase Fire Test

CML

ERROR

(P.398)

The

CML

error signal.

It is the difference
between

CML

REFERENCE

(P.396)

and

CML

FEEDBACK

(P.397).

Parameter Range:

n/a

Default Setting:

n/a

Parameter Type:

Output

OIM Menu Path(s):

Current Minor Loop (

CML

) -

CML

Test Points

CML

PI

LEAD

FREQUENCY

(P.302)

The lead break
frequency for the

CML

proportional-integral
(

PI

) block.

Parameter Range:

10 to 500

RAD

/

S

Default Setting:

100

RAD

/

S

Parameter Type:

Tunable

OIM Menu Path(s):

Current Minor Loop (

CML

) -

CML

Tuning

This parameter is set by the

CML

self-tuning procedure. You can also enter it

directly. Self-tuning will overwrite values entered manually.

CML

PI

PROP

GAIN

(P.301)

Proportional gain for
the

CML

proportional-

integral (

PI

) block.

Parameter Range:

0.000 to 4.000

Default Setting:

0.250

Parameter Type:

Tunable

OIM Menu Path(s):

Current Minor Loop (

CML

) -

CML

Tuning

This parameter is set by the

CML

self-tuning procedure. You can also enter it

directly. Self-tuning will overwrite values entered manually.