Hapter, Configuring parameters for the i/o expansion kit – Rockwell Automation FlexPak 3000 Digital DC Drive Version 4.3 User Manual
Page 117
Configuring Parameters for the I/O Expansion Kit
11-1
C
HAPTER
11
Configuring Parameters for the
I/O Expansion Kit
This section provides descriptions for parameters that are available when the I/O
Expansion kit is installed. For a kit description, see the I/O Expansion kit manual
(D2-3301).
For information on the
MOP
options available through the I/O Expansion kit, see
section 4.1.6, Configuring the Motor-Operated Potentiometer (MOP) Reference.
For information on the outer control loop options available through the I/O Expansion
kit, see chapter 9, Configuring the Outer Control Loop.
These parameters are only available if the I/O Expansion kit is installed.
I
/
O
EXPANSION
KIT
(P.797)
Indicates whether or
not the I/O Expansion
kit is installed in the
drive and if it has
passed diagnostics. If
the I/O Expansion kit
has failed
diagnostics, the drive
is not operable (the
armature cannot
become active).
Parameter Range:
NOT
INSTALLED
INSTALLED
FAILED
DIAGS
Default Setting:
n/a
Parameter Type:
Output
OIM Menu Path(s):
Input/Output - Frequency I/O
Input/Output - Analog I/O
Input/Output - Digital I/O
Drive Information