4-2

FlexPak 3000 DC Drive Software Reference

4.1

Configuring the Speed Reference Source Block

The speed reference can be either automatic or manual. An automatic (auto)
reference usually comes from a device such as a

PLC

or a network master. A manual

reference typically comes from a speed potentiometer or the

OIM

keypad. See the

OIM

manual for information on auto and manual references.

If an I/O Expansion kit is installed, the selected speed reference can be overridden by
a preset speed reference if selected (terminals 59 and 60). See section 4.1.7.

Table 4.1 shows the possible control source and reference source settings. It also

shows the display for the key indicator under

.

Most systems will use one primary reference source. For example, you might use a
network for your reference most of the time, but have the terminal strip reference
available for occasions when the network is not running or for troubleshooting.

The block diagram for the speed reference source is shown in figure 4.2.

!

ATTENTION: When switching from auto to manual or from manual to
auto, the drive will ramp to the reference level provided by the new source
at the rate specified by

ACCELERATION

TIME

(P.001) or

DECELERATION

TIME

(P.002). Be aware that an abrupt speed change might occur, depending
on the new reference and the rate specified in these parameters. Failure
to observe this precaution could result in bodily injury.

Table 4.1 – Effect of Control Source and Reference Settings

Control Source

Reference Set Through:

OIM

Key Indicator

OIM Reference Display

(Monitor Mode)

Units

KEYPAD

Automatic reference from the
terminal strip as set by

AUTO

REFERENCE

SELECT

(P.103)

AUTO

TERMBLK

REF

RPM

,

percentage,
or
user-defined
units

OIM

MANUAL

KEYPAD

REF

TERMBLK

(Regulator type is
speed/voltage)

Automatic reference from the
terminal strip as set by

AUTO

REFERENCE

SELECT

(P.103)

AUTO

TERMBLK

REF

Manual reference from the
terminal strip as set by

MANUAL

REF

SELECT

(P.106)

MANUAL

SERIAL

Automatic reference from the
terminal strip as set by

AUTO

REFERENCE

SELECT

(P.103)

AUTO

Serial device (

PC

)

MANUAL

SERIAL

REF

NETWORK

Network

AUTO

(Manual

not available)

NETWORK

REF

From
network

TERMBLK

(Regulator type is
current/torque)

Automatic reference from the
terminal strip as set by

AUTO

REFERENCE

SELECT

(P.103)

AUTO

(Manual

not available)

TORQUE

REF

MOTOR

LOAD

units