P.397), P.300), P.395) – Rockwell Automation FlexPak 3000 Digital DC Drive Version 4.3 User Manual

Page 77

Advertising
background image

Configuring the Current Minor Loop

6-7

CML

FEEDBACK

(P.397)

The

CML

feedback

signal after all
hardware and
software scaling.

Parameter Range:

n/a

Default Setting:

n/a

Parameter Type:

Output

OIM Menu Path(s):

Current Minor Loop (

CML

) -

SCR

Diagnostics -

Armature Phase Fire Test

Current Minor Loop (

CML

) -

CML

Feedback Scaling

Current Minor Loop (

CML

) -

CML

Test Points

CML

FEEDBACK

GAIN

ADJ

(P.300)

The

CML

feedback

gain adjustment. In
most cases, this is
set for unity gain.
Typically, it will be set
to 1.000.

Parameter Range:*

0.900 to 1.100

Default Setting:

1.000

Parameter Type:

Tunable

OIM Menu Path(s):

Current Minor Loop (

CML

) -

CML

Feedback Scaling

*The range might be affected by the software scaling factor calculated by the drive.

J

18

ARM

I

FB

RESISTOR

(P.395)

Indicates the burden
resistor position
required to properly
scale armature
current feedback.

Parameter Range:

1 (15

Ω)

2 (20

)

3 (30

)

4 (39

)

Default Setting:

n/a

Parameter Type:

Output

OIM Menu Path(s):

Drive Information – Correct Scaling Jumper Positions
Current Minor Loop (

CML

) –

CML

Feedback Scaling

Quick Start

The value of this parameter is based on the values of

CT

TURNS

RATIO

(P.010),

MAXIMUM

CURRENT

(P.007), and

MOTOR

RATED

ARM

AMPS

(P.008). If you change any

one of these parameters, check the reading of

J

18

ARM

I

FB

RESISTOR

and make

sure the setting of jumper J18 on the Regulator board matches.