P.214), 4 configuring speed loop feedback lead/lag block – Rockwell Automation FlexPak 3000 Digital DC Drive Version 4.3 User Manual

Page 59

Advertising
background image

Configuring the Speed/Voltage Loop

5-11

5.2.4 Configuring Speed Loop Feedback Lead/Lag Block

Lead/lag adjustments compensate for backlash or coupling issues because of the
feedback device.

To enable this block, set

SPD

LEADLAG

SELECT

(P.216) to

LEAD

/

LAG

or

LAG

/

LEAD

. To

disable this block, set

SPD

LEADLAG

SELECT

(P.216) to

BYPASS

.

When this block is enabled, the selected feedback signal is fed into the lead/lag block.
The

SPD

LEADLAG

LOW

FREQ

(P.214) and

SPD

LEADLAG

RATIO

(P.213) input values are

used to calculate the high break frequency.

SPD

LEADLAG

LOW

FREQ

(P.214) specifies

the low break frequency and the

SPD

LEADLAG

RATIO

(P.213) is the ratio maintained

between the low break and high break frequencies. The low break frequency and ratio
settings are multiplied to determine the high break frequency. For example, if the low
break frequency is 0.50rad/s and the ratio is 10, high break frequency is 5.00 rad/s.

The transfer functions for lead/lag and lag/lead are:

Lead/Lag:

Lag/Lead:

Where:

ω

low

=

SPD

LEADLAG

LOW

FREQ

(P.214)

ω

high

=

SPD

LEADLAG

LOW

FREQ

(P.214)

*

SPD

LEADLAG

RATIO

(P.213)

1

s

ω

low

----------

+

1

s

ω

high

------------

+

----------------------

1

s

ω

high

------------

+

1

s

ω

low

----------

+

----------------------

SPD

LEADLAG

LOW

FREQ

(P.214)

Specifies the low
break frequency of
the speed feedback
lead/lag block.

Parameter Range:

0.01 to 69.81

RAD

/

S

when:

FEEDBACK

SELECT

(P.200) =

ARMATURE

VOLT

SPD

LOOP

SCAN

TIME

(P.019) = 10

MS

0.01 to 139.62

RAD

/

S

when:

FEEDBACK

SELECT

(P.200)

ARMATURE

VOLT

SPD

LOOP

SCAN

TIME

(P.019) = 5

MS

Default Setting:

1.00

RAD

/

S

Parameter Type:

Tunable

OIM Menu Path(s):

Speed/Voltage Loop (

SPD

) - Speed/Voltage Loop

(

SPD

) Tuning

If

SPD

LEADLAG

SELECT

is set to:

BYPASS

: This parameter has no effect.

LAG

/

LEAD

: This parameter specifies the lead break frequency.

LEAD

/

LAG

: This parameter specifies the lag break frequency.