Rockwell Automation FlexPak 3000 Digital DC Drive Version 4.3 User Manual
Page 175
![background image](/manuals/581746/175/background.png)
C-13
SELF
TUNE
STABILITY
(P.219)
10 to 100
25
SPD
LEADLAG
LOW
FREQ
(P.214)
0.01 to 69.81
RAD
/
S
when:
•
FEEDBACK
SELECT
(P.200) =
ARMATURE
VOLT
•
SPD
LOOP
SCAN
TIME
(P.019) = 10
MS
0.01 to 139.62 rad/s when:
•
FEEDBACK
SELECT
(P.200)
≠
ARMATURE
VOLT
•
SPD
LOOP
SCAN
TIME
(P.019) = 5
MS
1.00
RAD
/
S
SPD
LEADLAG
RATIO
(P.213)
2 to 20
2
SPD
LEADLAG
SELECT
(P.216)
•
LEAD
/
LAG
•
BYPASS
•
LAG
/
LEAD
BYPASS
SPD
LOOP
LAG
BYPASS
(P.217)
•
ON
•
OFF
ON
SPD
LOOP
LAG
FREQ
(P.215)
.0.01 to 139.62
RAD
/
S
when:
•
FEEDBACK
SELECT
(P.200) =
ARMATURE
VOLT
•
SPD
LOOP
SCAN
TIME
(P.019) = 10
MS
0.01 to 279.67 rad/s when:
•
FEEDBACK
SELECT
(P.200)
≠
ARMATURE
VOLT
•
SPD
LOOP
SCAN
TIME
(P.019) = 5
MS
1.00
RAD
/
S
SPD
LOOP
PI
INIT
SEL
• 0 =
ZERO
• 1 =
SPD
LOOP
PI
INITI
VAL
• 2 =
ANALOG
MAN
TRIM
REF
(P.194)
0
SPD
LOOP
PI
INIT
VAL
–32768 to 32767
0
SPD
LOOP
PI
LEAD
FREQ
(P.212)
.0.01 to 282.74
RAD
/
S
when:
•
FEEDBACK
SELECT
(P.200) =
ARMATURE
VOLT
•
SPD
LOOP
SCAN
TIME
(P.019) = 10
MS
0.01 to 327.67 rad/s when:
•
FEEDBACK
SELECT
(P.200)
≠
ARMATURE
VOLT
•
SPD
LOOP
SCAN
TIME
(P.019) = 5
MS
3.00
RAD
/
S
SPD
LOOP
PI
PROP
GAIN
(P.211)
0.10 to 128.00
4.40
Table C.1 – Parameter Settings Quick Reference Table (Continued)
Parameter
Parameter Selection/
Adjustment Range
Initial Factory
Setting (Default)
Your Data
Date
Setting