FlexPak 3000 DC Drive Software Reference

OCL

TYPE

3

POSN

REG

EN

(P.814)

DISABLED

ENABLED

DISABLED

OPEN

SCR

SENSITIVITY

(P.600)

0 to 100%

50%

OPEN

SCR

TRIP

THRESH

(P.601)

800 to 4000

1600

PHASE

FIRE

TEST

DELTA

(P.309)

0 to 180

DEGREE

0

DEGREE

PHASE

FIRE

TST

BRIDGE

(P.310)

OFF

ON

OFF

PHASE

LOSS

DETECT

EN

(P.609)

DISABLE

ENABLE

ENABLE

PLL

MAXIMUM

ERROR

(P.308)

2 to 1000

µ

sec

2

µ

sec

POS

CURRENT

LIM

SEL

(P.223)

REGISTER

ANALOG

IN

1

ANALOG

IN

2

NETW

IN

REG

1

NETW

IN

REG

2

NETW

IN

REG

3

REGISTER

POSITIVE

CURRENT

LIM

(P.005)

0 to

MAXIMUM

CURRENT

(%

FLA

)

150 %

FLA

PRESET

SPEED

1 (P.117)

MINIMUM

SPEED

to

MAXIMUM

SPEED

(

RPM

or user-defined units)

250

RPM

PRESET

SPEED

2 (P.118)

MINIMUM

SPEED

to

MAXIMUM

SPEED

(

RPM

or user-defined units)

250

RPM

PRESET

SPEED

3 (P.119)

MINIMUM

SPEED

to

MAXIMUM

SPEED

(

RPM

or user-defined units)

250

RPM

PULSE

TACH

PPR

(P.207)

18 to 2500

PPR

18

PPR

PULSE

TACH

QUADRATURE

(P.208) •

ON

OFF

ON

RAMP

STOP

DECEL

TIME

(P.018)

0.1 to 300.0 seconds

5.0 seconds

REVERSE

DISABLE

(P.015)

OFF

ON

OFF

S

-

CURVE

ROUNDING

(P.014)

0 to 50%

0%

SELF

TUNE

BRIDGE

(P.220)

FORWARD

REVERSE

FORWARD

SELF

TUNE

FIELD

RANGE

(P.218)

0.90 to 5.00

1.00

Table C.1 – Parameter Settings Quick Reference Table (Continued)

Parameter

Parameter Selection/

Adjustment Range

Initial Factory

Setting (Default)

Your Data

Date

Setting