4.4.2 Configuring Current Compounding

Current compounding is used for load sharing between drives. If there is a change in
the

CML

feedback, current compounding either increases or decreases the speed

reference. See figure 4.7 for the block diagram.

CURRENT

COMPOUND

TP

(P.293)

The current
compounding value
that is subtracted
from the conditioned
speed reference.

Parameter Range:

n/a

Default Setting:

n/a

Parameter Type:

Output

OIM Menu Path(s):

Speed/Voltage Loop (

SPD

) - Speed/Voltage Loop

(

SPD

) - Test Points

CURRENT

COMPOUNDING

(P.209)

Sets the level of
current
compounding.

Parameter Range:

–50 to 50%

Default Setting:

0%

Parameter Type:

Tunable

OIM Menu Path(s):

Speed/Voltage Loop (

SPD

) - Speed Voltage Loop

(

SPD

) Tuning