9-10

FlexPak 3000 DC Drive Software Reference

OCL

FEEDBACK

SELECT

(P.804)

Selects the source of
the

OCL

feedback

signal.

Parameter Range:

NONE

CML

FEEDBACK

ANALOG

IN

1

ANALOG

IN

2

5 =

SPEED

LOOP

OUTPUT

6 =

ANALOG

AUTO

REFERENCE

7 =

NETWORK

IN

REG

1

8 =

NETWORK

IN

REG

2

9 =

NETWORK

IN

REG

3

Default Setting:

NONE

Parameter Type:

Configurable

OIM Menu Path(s):

Outer Control Loop (

OCL

) -

OCL

Configure

The choices are:

NONE

: The

OCL

feedback signal is fixed at 0.

CML

FEEDBACK

: Feedback is from an eight-sample average of the current minor

loop (

CML

) feedback signal.

ANALOG

IN

1 or 2: Feedback is from an I/O Expansion kit analog input. These are

only available if an I/O Expansion kit is installed.

The following options are available only if a network kit is installed:

5 (

SPEED

LOOP

OUTPUT

): Feedback is the

SPD

LOOP

OUTPUT

(P.299) value.

6 (

ANALOG

AUTO

REFERENCE

): Feedback is the

ANALOG

AUTO

REFERENCE

(P.188)

value.

7, 8, and 9 (

NETWORK

IN

REG

1, 2, and 3): Feedback is the associated network

input register.

OCL

LEADLAG

LOW

FREQ

(P.806)

Lead/lag block low
break frequency of
the outer control loop.

Parameter Range:

0.01 to 34.90

RAD

/

S

Default Setting:

1.00

RAD

/

S

Parameter Type:

Tunable

OIM Menu Path(s):

Outer Control Loop (

OCL

) -

OCL

Tuning

Sets the lead break frequency if

OCL

LEADLAG

SELECT

(P.805) is set to

LEAD

/

LAG

.

Sets the lag break frequency if

OCL

LEADLAG

SELECT

is set to

LAG

/

LEAD

.