Configuring the Outer Control Loop

9-9

9.3

Configuring the Outer Control Loop Feedback Path

The

OCL

lead and lag options allow you to limit ratio errors when the primary ratio

variable changes quickly. Lead/lag adjustments compensate for backlash or coupling
issues with the feedback device.

To enable lead/lag or lag/lead, set

OCL

LEADLAG

SELECT

to

LEAD

/

LAG

or

LAG

/

LEAD

,

respectively. To disable lead/lag or lag/lead, set

OCL

LEADLAG

SELECT

to

BYPASS

.

When lead/lag or lag/lead is selected, the

OCL

accepts a feedback signal from the

source selected by

OCL

FEEDBACK

SELECT

(P.804). You can check the value of this

signal through

OCL

FEEDBACK

(P.847).

OCL

FEEDBACK

is fed into the lead/lag block. In this block, the

OCL

LEADLAG

LOW

FREQ

(P.806) and

OCL

LEADLAG

RATIO

(P.807) values are applied to the signal and the drive

calculates the high break frequency.

OCL

LEADLAG

LOW

FREQ

sets where the signal will

break. The

OCL

LEADLAG

RATIO

is the ratio maintained between the low break and high

break frequency. The low frequency and ratio settings are multiplied to determine the
high break frequency. For example, if the low break frequency is 0.50 rad/s and the
ratio is 10, the high break frequency is 5.00 rad/s.

The transfer functions for lead/lag and lag/lead are:

!

ATTENTION: Lead/lag parameters must be adjusted by a qualified
control engineer. Failure to observe this precaution can result in severe
bodily injury or loss of life.

Lead/Lag:

Lag/Lead:

Where:

ω

low

=

OCL

LEADLAG

LOW

FREQ

(P.806)

ω

high

=

OCL

LEADLAG

LOW

FREQ

(P.806)

*

OCL

LEADLAG

RATIO

(P.807)

1

s

ω

low

----------

+

1

s

ω

high

------------

+

----------------------

1

s

ω

high

------------

+

1

s

ω

low

----------

+

----------------------

OCL

FEEDBACK

(P.847)

The feedback value
of the outer control
loop. It is displayed in

OCL

user-defined

units.

Parameter Range:

n/a

Default Setting:

n/a

Parameter Type:

Output

OIM Menu Path(s):

Outer Control Loop (

OCL

) -

OCL

Test Points