Configuring the Speed/Voltage Loop

5-5

IR

COMPENSATION

(P.206)

Sets the armature
voltage loss
compensation value
used when the drive
is configured as a
voltage regulator.

Parameter Range:

0 to 50%

Default Setting:

0%

Parameter Type:

Tunable

OIM Menu Path(s):

Speed/Voltage Loop (

SPD

) - Speed/Voltage Loop

(

SPD

) Tuning

Quick Start
Field - Field Current Regulator - Field Loop Tuning

This parameter is also used by the Field Current Regulator kit to set the
field-weakened threshold. See section 8.3.

IR

COMPENSATION

is normally determined from the motor data sheet. It should be

set to the percent

IR

drop of the motor.

If this data is not available on the motor data sheet, you can set this empirically so
that the no-load and full-load speeds are as close as possible when operating as a
voltage regulator.

IR

COMPENSATION

TP

(P.290)

The level of

IR

COMPENSATION

being

subtracted from the
measured armature
voltage.

Parameter Range:

n/a

Default Setting:

n/a

Parameter Type:

Output

OIM Menu Path(s):

Speed/Voltage Loop (

SPD

) - Speed/Voltage Loop

(

SPD

) Test Points

The value of

IR

COMPENSATION

TP

is determined by the equation:

MOTOR

RATED

ARM

VOLTS

(P.009)

The rated armature
voltage as it is listed
on the motor
nameplate.

Parameter Range:

160 to 675 volts

Default Setting:

240 volts

Parameter Type:

Configurable

OIM Menu Path(s):

Speed/Voltage Loop (

SPD

) - Speed/Voltage Loop

(

SPD

) Feedback

Quick Start

This must always be set properly, regardless of the setting of

FEEDBACK

SELECT

(P.200).

IR COMPENSATION TP

IR COMPENSATION

CML FEEDBACK

MAXIMUM CURRENT

10 000

,

------------------------------------------------------------------------------------------------------------------------------------------------------------------------------

=