Rockwell Automation FlexPak 3000 Digital DC Drive Version 4.3 User Manual

Page 136

Advertising
background image

13-4

FlexPak 3000 DC Drive Software Reference

F00009

CONTROLLER

THERMOSTAT

TRIP

Drive thermostat indicates high temperature (>50°C)

Possible causes:

•

Inadequate heat sink ventilation.

•

Inadequate cabinet ventilation.

•

Heat sink fan failure.

•

Damaged or disconnected drive thermostat wiring.

F00010

AC

LINE

SYNCHRONIZATION

FAULT

Three-phase AC line synchronization circuit failure.

Possible causes:

•

Blown AC line fuse(s).

•

AC line frequency not within required range of 48 to 62Hz.

•

Excessive AC line noise or distortion.

•

Unstable AC line frequency. See

PLL

MAXIMUM

ERROR

(P.308).

•

Disconnected, loosely connected or damaged J6 ribbon cable.

F00011

OIM

COMMUNICATIONS

TIMEOUT

The Regulator board was unable to communicate with the interface
module (

OIM

or

DCM

). (See the hardware manual for a description of

regulator status

LED

s that can pinpoint whether or not the interface module

is communicating.)

Possible causes:

•

Disconnected, loosely connected, or damaged interface module/serial
cable.

•

Regulator board failure.

F00012

ARMATURE

OVER

VOLTAGE

Armature voltage exceeded 125% of

MOTOR

RATED

ARM

VOLTS

(P.009).

Possible causes:

•

MOTOR

RATED

ARM

VOLTS

not set properly.

•

Improper voltage loop tuning.

•

ENHANCED

FLD

VOLT

ADJ

(P.500) set too high (Enhanced Field Supply kit

only).

F00013

NETWORK

COMMUNICATION

TIMEOUT

Network communications is missing or failed to communicate with master
(

CONTROL

SOURCE

SELECT

set to

NETWORK

).

Possible causes:

•

NETW

CONNECT

TYPE

(P.910) was changed from

BASIC

to

FULL

.

•

NETW

DROP

NUMBER

(P.900) was changed.

•

Network option cable connections are loose or not connected.

•

Network option board failed or master communications failed.

Table 13.1 – Fault Codes (Continued)

Code

OIM Display

Description