Rockwell Automation FlexPak 3000 Digital DC Drive Version 4.3 User Manual

Page 167

Advertising
background image

C-5

DIG

OUT

2

CONTACT

TYP

(P.412)

NORMAL

OPEN

NORMAL

CLOSED

NORMAL

OPEN

DIG

OUT

2

SELECT

(P.411)

LEVEL

DETECT

1

OUTPUT

LEVEL

DETECT

2

OUTPUT

IN

CURRENT

LIMIT

DRIVE

READY

NETW

COMM

STATUS

NETW

IN

REG

1 (

BIT

1)

NETW

IN

REG

2 (

BIT

1)

NETW

IN

REG

3 (

BIT

1)

LEVEL

DETECT

2

OUTPUT

ENHANCED

FLD

VOLT

ADJ

(P.500)

• 0 to 180 (J21 set to B-C)

• 0 to 120 (J21 set to A-C)

84
0 when the Field
Current
Regulator kit is
installed

FEEDBACK

SELECT

(P.200)

ARMATURE

VOLT

DC

TACH

PULSE

TACH

AC

TACH

ARMATURE

VOLT

FIELD

AUTO

WEAKEN

(P.517)

DISABLED

ENABLED

DISABLED

FIELD

DELTA

HIGH

LIM

(P.587)

0 to 180

DEGREE

130

DEGREE

FIELD

ECONOMY

DELAY

(P.501)

0 to 27 minutes

5 minutes

FIELD

ECONOMY

REF

(P.511)

0 to 100%

0%

FIELD

LOSS

THRESHOLD

(P.512)

• 50 to 100% of

MOTOR

HOT

FLD

AMPS

(P.510) when

FEEDBACK

SELECT

(P.200) is set to

ARMATURE

VOLT

• 0 to 100% of

MOTOR

HOT

FLD

AMPS

(P.510) when

FEEDBACK

SELECT

(P.200) is set to

DC

TACH

,

PULSE

TACH

, or

AC

TACH

60% of

MOTOR

HOT

FLD

AMPS

(P.510)

FIELD

PI

LEAD

FREQ

(P.515)

0 to 282.70

RAD

/

S

1.50

RAD

/

S

FIELD

PI

PROP

GAIN

(P.514)

0.10 to 128.00

0.50

FIELD

REF

REGISTER

(P.513)

0 to

MOTOR

HOT

FLD

AMPS

MOTOR

HOT

FLD

AMPS

Table C.1 – Parameter Settings Quick Reference Table (Continued)

Parameter

Parameter Selection/

Adjustment Range

Initial Factory

Setting (Default)

Your Data

Date

Setting