FlexPak 3000 DC Drive Software Reference

DIG

OUT

2

SELECT

(P.411)

Selects the signal
used to drive digital
output 2 (terminals
68 and 69 on the I/O
Expansion kit).

Parameter Range:

LEVEL

DETECT

1

OUTPUT

LEVEL

DETECT

2

OUTPUT

IN

CURRENT

LIMIT

DRIVE

READY

NETW

COMM

STATUS

NETW

IN

REG

1 (bit 1)

NETW

IN

REG

2 (bit 1)

NETW

IN

REG

3 (bit 1)

Default Setting:

LEVEL

DETECT

2

OUTPUT

Parameter Type:

Configurable

OIM Menu Path(s):

Input/Output - Digital I/O

LEVEL

DETECT

1 or 2

OUTPUT

: The state of the selected level detector output drives

digital output 2. The signal is from the I/O Expansion kit digital output 1 or 2. See
chapter 12, Configuring the Drive to Use Level Detectors for information.

IN

CURRENT

LIMIT

: The armature in-current-limit signal, which indicates whether or

not the drive is operating at the maximum allowable current, drives digital
output 2. See

CML

REF

LIMIT

SELECT

(P.311), for information.

DRIVE

READY

: The drive-is-ready signal drives digital output 2. This signal

indicates that the drive will start when the next run or jog command is received.

NETW

COMM

STATUS

: The state of

NETW

COMM

STATUS

(P.908) drives digital

output 2. See chapter 10 for description.

NETW

IN

REG

1, 2, or 3: Bit 0 of

NETW

IN

REG

1 (P.905), 2 (P.906), or 3 (P.907) drives

digital output 2. A network kit must be installed to select the network input registers.
Note that the network input registers are updated only when Control Source (P.000)
is set to

NETWORK

and the network is active. See chapter 10 for description.