5-10

FlexPak 3000 DC Drive Software Reference

PULSE

TACH

QUADRATURE

(P.208)

Enables or disables
pulse encoder
quadrature.

A quadrature pulse
encoder must be
used on regenerative
drives that use a
pulse encoder.

Parameter Range:

ON

OFF

Default Setting:

ON

Parameter Type:

Configurable

OIM Menu Path(s):

Speed/Voltage Loop (

SPD

) - Speed/Voltage Loop

(

SPD

) Feedback

Set

ON

for a bidirectional pulse encoder.

Set

OFF

for a unidirectional pulse encoder.

If

PULSE

TACH

QUADRATURE

is set to

OFF

and

PULSE

TACH

is the selected

FEEDBACK

SELECT

type,

NEGATIVE

CURRENT

LIM

(P.006) will be set to 0 and

REVERSE

DISABLE

(P.015) set to

ON

(preventing reverse direction).

PULSE

TACHOMETER

KIT

(P.798)

Indicates whether or
not the Pulse
Encoder
(Tachometer) kit is
installed in the drive
and if it has passed
diagnostics.

Parameter Range:

INSTALLED

NOT

INSTALLED

FAILED

DIAGS

Default Setting:

n/a

Parameter Type:

Output

OIM Menu Path(s):

Drive Information

If the Pulse Encoder (Tachometer) kit has failed diagnostics, the drive is not
operable (the armature cannot become active).

Advertising