P.208), P.798) – Rockwell Automation FlexPak 3000 Digital DC Drive Version 4.3 User Manual
Page 58
5-10
FlexPak 3000 DC Drive Software Reference
PULSE
TACH
QUADRATURE
(P.208)
Enables or disables
pulse encoder
quadrature.
A quadrature pulse
encoder must be
used on regenerative
drives that use a
pulse encoder.
Parameter Range:
ON
OFF
Default Setting:
ON
Parameter Type:
Configurable
OIM Menu Path(s):
Speed/Voltage Loop (
SPD
) - Speed/Voltage Loop
(
SPD
) Feedback
Set
ON
for a bidirectional pulse encoder.
Set
OFF
for a unidirectional pulse encoder.
If
PULSE
TACH
QUADRATURE
is set to
OFF
and
PULSE
TACH
is the selected
FEEDBACK
SELECT
type,
NEGATIVE
CURRENT
LIM
(P.006) will be set to 0 and
REVERSE
DISABLE
(P.015) set to
ON
(preventing reverse direction).
PULSE
TACHOMETER
KIT
(P.798)
Indicates whether or
not the Pulse
Encoder
(Tachometer) kit is
installed in the drive
and if it has passed
diagnostics.
Parameter Range:
INSTALLED
NOT
INSTALLED
FAILED
DIAGS
Default Setting:
n/a
Parameter Type:
Output
OIM Menu Path(s):
Drive Information
If the Pulse Encoder (Tachometer) kit has failed diagnostics, the drive is not
operable (the armature cannot become active).