P.792), P.793) – Rockwell Automation FlexPak 3000 Digital DC Drive Version 4.3 User Manual
Page 56
![background image](/manuals/581746/56/background.png)
5-8
FlexPak 3000 DC Drive Software Reference
J11
ANLG
TACH
VLT
SCL
(P.792)
Position in which to
set the J11 hardware
jumper based on the
values of
TOP
SPEED
(P.011) and
ANLG
TACH
VOLTS
/1000
(P.203).
Parameter Range:
16
31
62
125
250
Default Setting:
n/a
Parameter Type:
Output
OIM Menu Path(s):
Drive Information - Correct Scaling Jumper Positions
Quick Start
Speed/Voltage Loop (
SPD
) - Speed/Voltage Loop
(
SPD
) Feedback
J14
ANLG
TACH
VLT
RNG
(P.793)
Position in which to
set the J14 hardware
jumper based on the
values of
TOP
SPEED
(P.011) and
ANLG
TACH
VOLTS
/1000
(P.203).
Parameter Range:
LOW
HIGH
Default Setting:
n/a
Parameter Type:
Output
OIM Menu Path(s):
Drive Information - Correct Scaling Jumper Positions
Quick Start
Speed/Voltage Loop (
SPD
) - Speed/Voltage Loop
(
SPD
) Feedback
The tachometer wiring must match the setting shown here. See the hardware
manual for wiring information.