5-8

FlexPak 3000 DC Drive Software Reference

J11

ANLG

TACH

VLT

SCL

(P.792)

Position in which to
set the J11 hardware
jumper based on the
values of

TOP

SPEED

(P.011) and

ANLG

TACH

VOLTS

/1000

(P.203).

Parameter Range:

16
31
62
125
250

Default Setting:

n/a

Parameter Type:

Output

OIM Menu Path(s):

Drive Information - Correct Scaling Jumper Positions
Quick Start
Speed/Voltage Loop (

SPD

) - Speed/Voltage Loop

(

SPD

) Feedback

J14

ANLG

TACH

VLT

RNG

(P.793)

Position in which to
set the J14 hardware
jumper based on the
values of

TOP

SPEED

(P.011) and

ANLG

TACH

VOLTS

/1000

(P.203).

Parameter Range:

LOW

HIGH

Default Setting:

n/a

Parameter Type:

Output

OIM Menu Path(s):

Drive Information - Correct Scaling Jumper Positions
Quick Start
Speed/Voltage Loop (

SPD

) - Speed/Voltage Loop

(

SPD

) Feedback

The tachometer wiring must match the setting shown here. See the hardware
manual for wiring information.