Configuring the Outer Control Loop

9-3

DIG

IN

0 (P.490)

Indicates the state of
digital input 0
(terminal 12 on the
Regulator board).

Parameter Range:

ON

OFF

(see table 9.2 for detail)

Default Setting:

n/a

Parameter Type:

Output

OIM Menu Path(s):

Additional Parameters (listed by parameter number)

DIG

IN

0 is

ON

when +24VDC is applied for more than 10 msec. It is

OFF

when 0VDC

is applied.

Table 9.2 – Conditions Indicated by

DIG

IN

0 (P.490)

DIG

IN

0

SELECT

(P.428)

Setting

Condition if

DIG

IN

0 (P.490) Reads:

ON

OFF

BRUSH

WEAR

INPUT

OK

Worn

JOG

SPEED

SELECT

Jog Speed 2 active

Jog Speed 1 active

OCL

ENABLE

OCL

enabled

OCL

disabled

DIG

IN

0

SELECT

(P.428)

Determines which
function is controlled
by digital input 0
(terminal 12 on the
Regulator board).

Parameter Range:

1 =

BRUSH

WEAR

INPUT

2 =

JOG

SPEED

SELECT

3 =

OCL

ENABLE

Default Setting:

1

Parameter Type:

Configurable

OIM Menu Path(s):

Additional Parameters (listed by parameter number)

The signal can be:

OCL

ENABLE

: Enables the outer control loop if

CONTROL

SOURCE

SELECT

is not set

to

NETWORK

and if the I/O Expansion kit is not installed.

BRUSH

WEAR

: The input is from a brush wear indicator. If the input is

OFF

, the

MOTOR

BRUSH

WEAR

LOW

alarm is generated. You must have the E.S.P. Brush

Monitor Detector kit installed to use this option.

JOG

SPEED

SELECT

: The input determines whether

JOG

SPEED

1 (P.012) or

JOG

SPEED

2 (P.017) will be used when the drive is jogging.