Eq (ecam quit (disengage)), Motion – Yaskawa LEGEND-MC User Manual

Page 119

Advertising
background image

109

LEGEND-MC User’s Manual

EQ (ECam Quit (Disengage))

[Motion]

DESCRIPTION:

The EQ command disengages an electronic cam slave axis at the specified master position. If a value is
specified outside of the master’s range, the slave will disengage immediately.

ARGUMENTS: EQ n

where

n is the master position at which the axis is to be disengaged.

“?” contains a 1 if engage command issued and slave is waiting to engage, 2 if disengage command issued
and slave is waiting to disengage, and 0 if ECAM engaged or disengaged.

USAGE:

OPERAND USAGE:

_EQn contains 1 if engage command is issued and slave is waiting to engage, 2 if disengage command is
issued and slave is waiting to disengage, and 0 if ECAM engaged or disengaged.

RELATED COMMANDS:

EXAMPLES:

NOTE: This command is not a trippoint. This command will not hold the execution of the program
flow. If the execution needs to be held until master position is reached, use MF or MR command.

While Moving

Yes

Minimum value

-2147483647

In a Program

Yes

Maximum value

2147483648

Command Line

Yes

Default Value

--

Can be Interrogated

Yes

Default Format

--

Used as an Operand

Yes

Distributed Control

Specific Axis

"EB" Enable

Ecam

"EG" Engage

Ecam

"EM" Specify

Ecam

Cycle

"EP"

CAM table intervals & starting point

"ET"

Electronic CAM table

EQ 300

Disengages the motor at master position 300.