Sc (stop code), Status – Yaskawa LEGEND-MC User Manual

Page 217

Advertising
background image

207

LEGEND-MC User’s Manual

SC (Stop Code)

[Status]

DESCRIPTION:

The SC command allows the user to determine why a motor stops. The controller responds with the stop
code as follows:

ARGUMENTS: SC XYZW or ABCDEFGH

USAGE:

OPERAND USAGE:

_SCn contains the value of the stop code where n is an axis letter.

EXAMPLES:

CODE

MEANING

CODE

MEANING

0

Motors are running, independent
mode

11

Stopped by selective Abort
Input

1

Motors stopped at commanded
independent position

40

Stopped at Latch Target

2

Decelerating or stopped by FWD
limit switch or software limit, FL

41

Latch Target failed because
of Limit Switch or Stop
Command

3

Decelerating or stopped by REV limit
switch or software limit, BL

42

Latch Target overrun
because of insufficient
distance

4

Decelerating or stopped by Stop
Command (ST)

50

Contour running

6

Stopped by Abort input

51

Contour Stop

7

Stopped by Abort command (AB)

99

MC timeout

8

Decelerating or stopped by Off-on-
Error (OE1)

100

Motors are running, vector
sequence

9

Stopped after Finding Edge (FE)

101

Motors stopped at
commanded vector

10

Stopped after Homing (HM)

While Moving

Yes

Default Value

---

In a Program

Yes

Default Format

3.0

Command Line

Yes

Can be Interrogated

No

Used as an Operand

Yes

Distributed Control

QW Packet

Tom=_SCX

Assign the Stop Code to variable Tom