[Motion]

DESCRIPTION:

AB (Abort) stops motion instantly without controlled deceleration by freezing the profiler. If there is a
program executing, AB also aborts the program unless a 1 argument is specified. The command, AB, will
shut off the motors (disable the amplifier) for any axis in which the off-on-error function is enabled (see
command "OE"). AB aborts motion on all axes in motion and cannot stop individual axes. If a multi-axis
system is configured (distributed control) the AB command will abort all axes if issued to the master.

ARGUMENTS: AB n

where

n = 0 aborts motion and program

n = 1 aborts motion without aborting program

n = 2 aborts motion on all axes that are connected via ethernet, does not cause error for axes that have lost

connection.

USAGE:

OPERAND USAGE:

_AB returns the state of the Abort Input on the local controller.

RELATED COMMANDS:

EXAMPLES:

NOTE: Use parameter 1 following AB if you want the motion to be aborted or application program will be aborted.

While Moving

Yes

Default Value

n/a

In a Program

Yes

Default Format

n/a

Command Line

Yes

Can be Interrogated

Yes

Used as an Operand

Yes

Distributed Control

Out to all axes

"SH"

Turns servos back on if they were shut-off by
Abort and OE1.

OE 0,0,0,0

Disable OFF/ON error for all axes

AB

Aborts motion unconditionally, motors remain
enabled

OE 1,1,1,1

Enable off-on-error

AB

Shuts off amplifier enable and aborts motion

#A

Label - Start of program

JG 20000

Specify jog speed on X-axis

BGX

Begin jog on X-axis

WT 5000

Wait 5000 msec

AB1

Abort motion without aborting program

WT 5000

Wait 5000 milliseconds

SH

Servo Here

JP #A

Jump to Label A

EN

End of the routine