328

LEGEND-MC User’s Manual

Example - Electronic Gearing LEGEND-MC

Objective: Run a geared motor at a speed of 1.132 times the speed of an external master. The master is
driven at speeds between 0 and 1800 RPM (2000 counts/rev encoder), and is connected through the
auxiliary encoder inputs.

Solution: Use a LEGEND-MC controller, where the X-axis auxiliary is master and X-axis main is geared
axis.

Now suppose the gear ratio of the X-axis is to change on-the-fly to 2. This can be achieved by
commanding:

Contour Mode Example

A complete program to generate the contour movement in this example is given below. To generate an
array, compute the position value at intervals of 8 ms. This is stored at the array POS. Then, the difference
between the positions is computed and is stored in the array DIF. Finally the motors are run in the contour
mode.

GR 1.132

Specify gear ratio

GR 2

Specify gear ratio for X axis to be 2

Instruction

Interpretation

#POINTS

Program defines X points

DM POS[16]

Allocate memory

DM DIF[15]

C=0

Set initial conditions, C is index

T=0

T is time in ms

#A

V1=50*T

V2=3*T

Argument in degrees

V3=-
955*@SIN[V2]+V1

Compute position

V4=@INT[V3]

Integer value of V3

POS[C]=V4

Store in array POS

T=T+8

C=C+1

JP #A,C<16

#B

Program to find position differences

C=0