Ta (tell alarm), Status – Yaskawa LEGEND-MC User Manual

Page 223

Advertising
background image

213

LEGEND-MC User’s Manual

TA (Tell Alarm)

[Status]

DESCRIPTION:

The TA command checks the alarm output of the amplifier on the side connector. If no alarm is present, the
controller returns 153 decimal, or 99 hex, which is the code for “No Alarm.” If the alarm output is active,
the controller requests the alarm code serially from the amplifier via the mating connector. See the Sigma
II documentation for all the possible alarm codes.

NOTE: The amplifier requires special firmware to transmit the alarm code to the controller. Consult the
factory for details. Firmware in the amplifier is not field upgradable.

ARGUMENTS: None

USAGE:

RELATED COMMANDS:

EXAMPLES:

While Moving

Yes

Default Value

---

In a Program

Yes

Default Format

---

Command Line

Yes

Can be Interrogated

Yes

Used as an Operand

Yes

Distributed Control

Use SA

"TS" Tell

Switches

"TC" Tell

Code

"TB" Tell

Byte

FAULT=_TA

Store amp alarm into a user variable