Example - Jog in X only
Jog X motor at 50000 count/s. After X motor is at its jog speed, begin jogging Z in reverse direction at
25000 count/s.
Homing Example (HM method):
Instruction
Interpretation
#A
Label
AC 20000,20000
Specify X,Y acceleration of 20000 cts / sec
DC 20000,20000
Specify X,Y deceleration of 20000 cts / sec
JG 50000,-25000
Specify jog speed and direction for X and Y axis
BG X
Begin X motion
AS X
Wait until X is at speed
BG Z
Begin Z motion
EN
Instruction
Interpretation
#HOME
Label
AC 1000000
Acceleration Rate
DC 1000000
Deceleration Rate
SP 5000
Speed for Home Search
HM X
Home X
BG X
Begin Motion
AM X
After Complete
MG "AT HOME"
Send Message
EN
End
#EDGE
Label
AC 2000000
Acceleration rate
DC 2000000
Deceleration rate
SP 8000
Speed
FE Y
Find edge command
BG Y
Begin motion
AM Y
After complete
MG "FOUND HOME"
Send message
DP,0
Define position as 0
EN
End