Va (vector acceleration), Motion, Va contains the value of the vector acceleration – Yaskawa LEGEND-MC User Manual
Page 244

234
LEGEND-MC User’s Manual
VA (Vector Acceleration)
[Motion]
DESCRIPTION:
This command sets the acceleration rate of the vector in a coordinated motion sequence.
ARGUMENTS: VA n
where
n is an unsigned integer. The parameter input will be rounded down to the nearest factor of 1024. The units
of the parameter is counts per second squared.
USAGE:
OPERAND USAGE:
_VA contains the value of the vector acceleration.
RELATED COMMANDS:
EXAMPLES:
While Moving
Yes
Minimum n Value
1024
In a Program
Yes
Maximum n Value
67107840
Command Line
Yes
Default Value
256000
Can be Interrogated
Yes
Default Format
Position Format
Used as an Operand
Yes
Distributed Control
No, Local
"VS" Vector
Speed
"VP" Vector
Position
"VE" End
Vector
"VM" Vector
Mode
"BGS" Begin
Sequence
"VD" Vector
Deceleration
"VS"
Vector smoothing constant - S-curve
VA 1024
Set vector acceleration to 1024 counts/sec
2
VA ?
Return vector acceleration
00001024
VA 20000
Set vector acceleration
VA ?
0019456
Return vector acceleration
ACCEL=_VA
Assign variable, ACCEL, the value of VA