At (after time), Trippoint, N is a signed integer – Yaskawa LEGEND-MC User Manual

Page 78: N = 0 defines a reference time at current time, Positive n waits n msec from reference, At -n is equivalent to at n; at 0), The following commands are sent sequentially

Advertising
background image

68

LEGEND-MC User’s Manual

AT (After Time)

[Trippoint]

DESCRIPTION:

The AT command is a trippoint which is used to hold up execution of the next command until after the
specified time has elapsed. The time is measured with respect to a defined reference time. AT 0 establishes
the initial reference. AT n specifies n msec from the reference. AT -n specifies n msec from the reference
and establishes a new reference after the elapsed time period. This command is useful for waiting an
accurate amount of time duration while still being able to perform some other operations as long as they
require less time than the AT time.

ARGUMENTS: AT n

where

n is a signed integer

n = 0 defines a reference time at current time

positive n waits n msec from reference

negative n waits n msec from reference and sets new reference after elapsed time period

(AT -n is equivalent to AT n; AT 0)

USAGE:

EXAMPLES:

The following commands are sent sequentially:

While Moving

Yes

Minimum Value

-2147483647

In a Program

Yes

Maximum Value

2147483647

Command Line

Yes

Default Value

---

Can be Interrogated

No

Default Format

---

Used as an Operand

No

Distributed Control

No, Local

AT 0

Establishes reference time 0 as current time

AT 50

Waits 50 msec from reference 0

AT 100

Waits 100 msec from reference 0

AT -150

Waits 150 msec from reference 0 and sets new
reference at 150

AT 80

Waits 80 msec from new reference (total
elapsed time is 230 msec)

Advertising