Tm (time base), Configuration, Tm contains the value of the sample time – Yaskawa LEGEND-MC User Manual
Page 235

225
LEGEND-MC User’s Manual
TM (Time Base)
[Configuration]
DESCRIPTION:
The TM command sets the sampling period of the control loop. Changing the sampling period will
uncalibrate the speed and acceleration parameters. A negative number turns off the internal clock allowing
for an external source to be used as the time base. The units of this command are
µsec. If a multi-axis
system is configured the TM value is set in all controllers if set in the master.
ARGUMENTS: TM n
where
n is an integer in microseconds with a resolution of 125 microseconds.
USAGE:
OPERAND USAGE:
_TM contains the value of the sample time.
EXAMPLES:
NOTE: Although this manual refers to times in msec, think in terms of servo cycles. This includes
everything from a WT command to SP commands.
While Moving
Yes
Minimum n Value
250
In a Program
Yes
Maximum n Value
20,000
Command Line
Yes
Default Value
1000
Can be Interrogated
Yes
Default Format
5.0
Used as an Operand
Yes
Distributed Control
No, Local
TM 250
Set sample rate to 250
µsec (This will multiply all
speeds by four and all acceleration by eight)
TM 1000
Return to default sample rate